{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"MGE EPS 8000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy PW","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE EPS 6000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy 4000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Comet 3000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE EPS 7000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Comet UPS","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy 5000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy 3000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy 6000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE Galaxy 9000","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"MGE STS(Upsilon and Epsilon)","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}}],"affected_systems_content":null,"content":"## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des\ncorrectifs (cf. section Documentation).\n","cves":[{"name":"CVE-2018-7244","url":"https://www.cve.org/CVERecord?id=CVE-2018-7244"},{"name":"CVE-2018-7245","url":"https://www.cve.org/CVERecord?id=CVE-2018-7245"},{"name":"CVE-2018-7246","url":"https://www.cve.org/CVERecord?id=CVE-2018-7246"},{"name":"CVE-2018-7243","url":"https://www.cve.org/CVERecord?id=CVE-2018-7243"}],"links":[],"reference":"CERTFR-2018-AVI-136","revisions":[{"description":"Version initiale","revision_date":"2018-03-19T00:00:00.000000"}],"risks":[{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans SCADA Schneider\nElectric MGE SNMP/Web Card 66074. Elles permettent \u00e0 un attaquant de\nprovoquer un contournement de la politique de s\u00e9curit\u00e9 et une atteinte \u00e0\nla confidentialit\u00e9 des donn\u00e9es.\n","title":"Multiples vuln\u00e9rabilit\u00e9s dans SCADA Schneider Electric MGE SNMP/Web Card 66074","vendor_advisories":[{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 SCADA Schneider Electric du 15 mars 2018","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Id=9555017105&p_File_Name=SEVD-2018-074-01+MGE+Network+Management+Card+Transverse+66074+installed+in+MGE+UPS+and+MGE+STS.pdf&p_Reference=SEVD-2018-074-01"}]}