{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"EcoStruxure Control Expert (incluant le produit Unity Pro) versions ant\u00e9rieures \u00e0 15.1 HF001","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"X80 advanced RTU Communication Module (BMENOR2200H) versions ant\u00e9rieures \u00e0 2.0.1","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"OPC UA Modicon Communication Module (BMENUA0100) versions 1.10 et ant\u00e9rieures : L'\u00e9diteur ne propose pas de correctif, se r\u00e9f\u00e9rer aux mesures de contournement","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"EcoStruxure Process Expert (incluant le produit HDCS) versions ant\u00e9rieures \u00e0 2021","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}}],"affected_systems_content":null,"content":"## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des\ncorrectifs (cf. section Documentation).\n","cves":[{"name":"CVE-2021-21814","url":"https://www.cve.org/CVERecord?id=CVE-2021-21814"},{"name":"CVE-2022-34760","url":"https://www.cve.org/CVERecord?id=CVE-2022-34760"},{"name":"CVE-2021-21830","url":"https://www.cve.org/CVERecord?id=CVE-2021-21830"},{"name":"CVE-2021-22797","url":"https://www.cve.org/CVERecord?id=CVE-2021-22797"},{"name":"CVE-2022-34762","url":"https://www.cve.org/CVERecord?id=CVE-2022-34762"},{"name":"CVE-2021-21828","url":"https://www.cve.org/CVERecord?id=CVE-2021-21828"},{"name":"CVE-2021-21810","url":"https://www.cve.org/CVERecord?id=CVE-2021-21810"},{"name":"CVE-2021-21813","url":"https://www.cve.org/CVERecord?id=CVE-2021-21813"},{"name":"CVE-2022-34761","url":"https://www.cve.org/CVERecord?id=CVE-2022-34761"},{"name":"CVE-2021-21825","url":"https://www.cve.org/CVERecord?id=CVE-2021-21825"},{"name":"CVE-2022-34759","url":"https://www.cve.org/CVERecord?id=CVE-2022-34759"},{"name":"CVE-2021-21829","url":"https://www.cve.org/CVERecord?id=CVE-2021-21829"},{"name":"CVE-2022-34764","url":"https://www.cve.org/CVERecord?id=CVE-2022-34764"},{"name":"CVE-2022-34763","url":"https://www.cve.org/CVERecord?id=CVE-2022-34763"},{"name":"CVE-2021-21826","url":"https://www.cve.org/CVERecord?id=CVE-2021-21826"},{"name":"CVE-2021-21812","url":"https://www.cve.org/CVERecord?id=CVE-2021-21812"},{"name":"CVE-2021-21827","url":"https://www.cve.org/CVERecord?id=CVE-2021-21827"},{"name":"CVE-2022-26507","url":"https://www.cve.org/CVERecord?id=CVE-2022-26507"},{"name":"CVE-2022-34765","url":"https://www.cve.org/CVERecord?id=CVE-2022-34765"},{"name":"CVE-2021-21815","url":"https://www.cve.org/CVERecord?id=CVE-2021-21815"},{"name":"CVE-2021-21811","url":"https://www.cve.org/CVERecord?id=CVE-2021-21811"}],"links":[{"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2022-193-01 du 12 juillet 2022","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules_Security_Notification_V3.0.pdf"},{"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2021-257-01 mis \u00e0 jour le 12 juillet 2022","url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-257-01_EcoStruxure_Control_Expert_EcoStruxure_Process_Expert_SCADAPack_Security_Notification_V3.0.pdf"},{"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric\u00a0SEVD-2021-222-02 mis \u00e0 jour le 12 juillet 2022","url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-222-02_AT%26T_Labs-XMILX_DEMILL_Eco_Struxure_Control_ExpertEco_Struxure_Process_Expert_SCADA_Pack_RemoteConnect_x70_Security_Notification_V4.0.pdf"}],"reference":"CERTFR-2022-AVI-646","revisions":[{"description":"Version initiale","revision_date":"2022-07-15T00:00:00.000000"},{"description":"Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-01 du 12 juillet 2022.","revision_date":"2022-08-19T00:00:00.000000"}],"risks":[{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"Atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es"},{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"},{"description":"\u00c9l\u00e9vation de privil\u00e8ges"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d'entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric","vendor_advisories":[{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-222-02 mis \u00e0 jour le 12 juillet 2022","url":null},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-193-01 du 12 juillet 2022","url":null},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-257-01 mis \u00e0 jour le 12 juillet 2022","url":null}]}