{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"Modicon Controllers M251 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11737","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon Controllers M241 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11737","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"PFXST6000, PFXSTM6000, PFXSP5000, PFXGP4100 series runtme  Pro-face BLUE pour la vuln\u00e9rabilit\u00e9 CVE-2024-11999","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Harmony/Magelis HMIST6, HMISTM6, HMIG3U, HMIG3X, HMISTO7 series avec runtime EcoStruxureTM Operator Terminal Expert pour la vuln\u00e9rabilit\u00e9 CVE-2024-11999","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon Controllers LMC058 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11737","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon Controllers M258 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11737","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}}],"affected_systems_content":"","content":"## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des correctifs (cf. section Documentation).","cves":[{"name":"CVE-2024-11999","url":"https://www.cve.org/CVERecord?id=CVE-2024-11999"},{"name":"CVE-2024-11737","url":"https://www.cve.org/CVERecord?id=CVE-2024-11737"}],"links":[],"reference":"CERTFR-2024-AVI-1053","revisions":[{"description":"Version initiale","revision_date":"2024-12-10T00:00:00.000000"}],"risks":[{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"Atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es"},{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d'entre elles permettent \u00e0 un attaquant de provoquer un d\u00e9ni de service \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et une atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es.","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric","vendor_advisories":[{"published_at":"2024-12-10","title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-345-02","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-02.pdf"},{"published_at":"2024-12-10","title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-345-03","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-03.pdf"}]}
