{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"SCALANCE XR322-12 (6GK5334-3TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC424-4 (6GK5428-4TR00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC432 (6GK5432-0GR00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCH328 (6GK5328-4TS01-2EC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM324 (6GK5324-8TS01-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 (6GK5328-4TS00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC424-4 (6GK5428-4TR00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCH328 (6GK5328-4TS01-2EC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC316-8 (6GK5324-8TS00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC316-8 (6GK5324-8TS00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM328 (6GK5328-4TS01-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC432 (6GK5432-0GR00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 (6GK5328-4TS00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC332 (6GK5332-0GA00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC S7-1500 versions sup\u00e9rieures ou \u00e9gales \u00e0V3.1.5 pour les vuln\u00e9rabilit\u00e9s CVE-2021-41617, CVE-2023-4527, CVE-2023-4806, CVE-2023-4911, CVE-2023-5363, CVE-2023-6246, CVE-2023-6779, CVE-2023-6780, CVE-2023-28531, CVE-2023-38545, CVE-2023-38546, CVE-2023-44487, CVE-2023-46218, CVE-2023-46219, CVE-2023-48795, CVE-2023-51384, CVE-2023-51385, CVE-2023-52927, CVE-2024-2961, CVE-2024-6119, CVE-2024-6387, CVE-2024-12133, CVE-2024-12243, CVE-2024-24855, CVE-2024-26596, CVE-2024-28085, CVE-2024-33599, CVE-2024-33600, CVE-2024-33601, CVE-2024-33602, CVE-2024-34397, CVE-2024-37370, CVE-2024-37371, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50246, CVE-2024-53166, CVE-2024-57977, CVE-2024-57996, CVE-2024-58005, CVE-2025-4373, CVE-2025-4598, CVE-2025-21701, CVE-2025-21702, CVE-2025-21712, CVE-2025-21724, CVE-2025-21728, CVE-2025-21745, CVE-2025-21756, CVE-2025-21758, CVE-2025-21765, CVE-2025-21766, CVE-2025-21767, CVE-2025-21795, CVE-2025-21796, CVE-2025-21848, CVE-2025-21862, CVE-2025-21864, CVE-2025-21865, CVE-2025-26465, CVE-2025-31115 et CVE-2025-46836.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM328 (6GK5328-4TS01-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC416-8 (6GK5424-8TR00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM332 (6GK5332-0GA01-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM332 (6GK5332-0GA01-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC416-8 (6GK5424-8TR00-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-4AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-2AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XCM324 (6GK5324-8TS01-2AC2) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-3AR3) versions ant\u00e9rieures \u00e0 V3.1","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC332 (6GK5332-0GA00-2AC2) versions ant\u00e9rieures \u00e0 V3.2","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}}],"affected_systems_content":"","content":"## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des correctifs (cf. section Documentation).","cves":[{"name":"CVE-2024-37370","url":"https://www.cve.org/CVERecord?id=CVE-2024-37370"},{"name":"CVE-2024-41797","url":"https://www.cve.org/CVERecord?id=CVE-2024-41797"},{"name":"CVE-2025-26465","url":"https://www.cve.org/CVERecord?id=CVE-2025-26465"},{"name":"CVE-2025-31115","url":"https://www.cve.org/CVERecord?id=CVE-2025-31115"},{"name":"CVE-2023-46218","url":"https://www.cve.org/CVERecord?id=CVE-2023-46218"},{"name":"CVE-2023-28531","url":"https://www.cve.org/CVERecord?id=CVE-2023-28531"},{"name":"CVE-2023-6780","url":"https://www.cve.org/CVERecord?id=CVE-2023-6780"},{"name":"CVE-2023-51385","url":"https://www.cve.org/CVERecord?id=CVE-2023-51385"},{"name":"CVE-2023-38546","url":"https://www.cve.org/CVERecord?id=CVE-2023-38546"},{"name":"CVE-2024-33602","url":"https://www.cve.org/CVERecord?id=CVE-2024-33602"},{"name":"CVE-2025-40568","url":"https://www.cve.org/CVERecord?id=CVE-2025-40568"},{"name":"CVE-2025-21796","url":"https://www.cve.org/CVERecord?id=CVE-2025-21796"},{"name":"CVE-2023-52927","url":"https://www.cve.org/CVERecord?id=CVE-2023-52927"},{"name":"CVE-2025-21864","url":"https://www.cve.org/CVERecord?id=CVE-2025-21864"},{"name":"CVE-2024-45492","url":"https://www.cve.org/CVERecord?id=CVE-2024-45492"},{"name":"CVE-2024-24855","url":"https://www.cve.org/CVERecord?id=CVE-2024-24855"},{"name":"CVE-2025-40569","url":"https://www.cve.org/CVERecord?id=CVE-2025-40569"},{"name":"CVE-2024-58005","url":"https://www.cve.org/CVERecord?id=CVE-2024-58005"},{"name":"CVE-2025-21712","url":"https://www.cve.org/CVERecord?id=CVE-2025-21712"},{"name":"CVE-2025-4373","url":"https://www.cve.org/CVERecord?id=CVE-2025-4373"},{"name":"CVE-2025-4598","url":"https://www.cve.org/CVERecord?id=CVE-2025-4598"},{"name":"CVE-2023-44487","url":"https://www.cve.org/CVERecord?id=CVE-2023-44487"},{"name":"CVE-2023-6779","url":"https://www.cve.org/CVERecord?id=CVE-2023-6779"},{"name":"CVE-2023-5363","url":"https://www.cve.org/CVERecord?id=CVE-2023-5363"},{"name":"CVE-2024-33600","url":"https://www.cve.org/CVERecord?id=CVE-2024-33600"},{"name":"CVE-2025-21728","url":"https://www.cve.org/CVERecord?id=CVE-2025-21728"},{"name":"CVE-2025-21767","url":"https://www.cve.org/CVERecord?id=CVE-2025-21767"},{"name":"CVE-2024-33599","url":"https://www.cve.org/CVERecord?id=CVE-2024-33599"},{"name":"CVE-2024-57996","url":"https://www.cve.org/CVERecord?id=CVE-2024-57996"},{"name":"CVE-2023-46219","url":"https://www.cve.org/CVERecord?id=CVE-2023-46219"},{"name":"CVE-2025-21766","url":"https://www.cve.org/CVERecord?id=CVE-2025-21766"},{"name":"CVE-2024-45490","url":"https://www.cve.org/CVERecord?id=CVE-2024-45490"},{"name":"CVE-2023-48795","url":"https://www.cve.org/CVERecord?id=CVE-2023-48795"},{"name":"CVE-2024-45491","url":"https://www.cve.org/CVERecord?id=CVE-2024-45491"},{"name":"CVE-2025-21745","url":"https://www.cve.org/CVERecord?id=CVE-2025-21745"},{"name":"CVE-2025-21795","url":"https://www.cve.org/CVERecord?id=CVE-2025-21795"},{"name":"CVE-2025-21758","url":"https://www.cve.org/CVERecord?id=CVE-2025-21758"},{"name":"CVE-2024-26596","url":"https://www.cve.org/CVERecord?id=CVE-2024-26596"},{"name":"CVE-2023-4527","url":"https://www.cve.org/CVERecord?id=CVE-2023-4527"},{"name":"CVE-2025-21848","url":"https://www.cve.org/CVERecord?id=CVE-2025-21848"},{"name":"CVE-2024-53166","url":"https://www.cve.org/CVERecord?id=CVE-2024-53166"},{"name":"CVE-2025-46836","url":"https://www.cve.org/CVERecord?id=CVE-2025-46836"},{"name":"CVE-2025-21862","url":"https://www.cve.org/CVERecord?id=CVE-2025-21862"},{"name":"CVE-2025-40567","url":"https://www.cve.org/CVERecord?id=CVE-2025-40567"},{"name":"CVE-2024-33601","url":"https://www.cve.org/CVERecord?id=CVE-2024-33601"},{"name":"CVE-2024-28085","url":"https://www.cve.org/CVERecord?id=CVE-2024-28085"},{"name":"CVE-2024-57977","url":"https://www.cve.org/CVERecord?id=CVE-2024-57977"},{"name":"CVE-2024-6119","url":"https://www.cve.org/CVERecord?id=CVE-2024-6119"},{"name":"CVE-2025-21765","url":"https://www.cve.org/CVERecord?id=CVE-2025-21765"},{"name":"CVE-2023-4806","url":"https://www.cve.org/CVERecord?id=CVE-2023-4806"},{"name":"CVE-2025-21702","url":"https://www.cve.org/CVERecord?id=CVE-2025-21702"},{"name":"CVE-2025-21865","url":"https://www.cve.org/CVERecord?id=CVE-2025-21865"},{"name":"CVE-2025-21724","url":"https://www.cve.org/CVERecord?id=CVE-2025-21724"},{"name":"CVE-2025-21701","url":"https://www.cve.org/CVERecord?id=CVE-2025-21701"},{"name":"CVE-2024-12243","url":"https://www.cve.org/CVERecord?id=CVE-2024-12243"},{"name":"CVE-2023-4911","url":"https://www.cve.org/CVERecord?id=CVE-2023-4911"},{"name":"CVE-2024-6387","url":"https://www.cve.org/CVERecord?id=CVE-2024-6387"},{"name":"CVE-2023-51384","url":"https://www.cve.org/CVERecord?id=CVE-2023-51384"},{"name":"CVE-2021-41617","url":"https://www.cve.org/CVERecord?id=CVE-2021-41617"},{"name":"CVE-2024-50246","url":"https://www.cve.org/CVERecord?id=CVE-2024-50246"},{"name":"CVE-2024-34397","url":"https://www.cve.org/CVERecord?id=CVE-2024-34397"},{"name":"CVE-2023-6246","url":"https://www.cve.org/CVERecord?id=CVE-2023-6246"},{"name":"CVE-2024-2961","url":"https://www.cve.org/CVERecord?id=CVE-2024-2961"},{"name":"CVE-2024-12133","url":"https://www.cve.org/CVERecord?id=CVE-2024-12133"},{"name":"CVE-2025-21756","url":"https://www.cve.org/CVERecord?id=CVE-2025-21756"},{"name":"CVE-2024-37371","url":"https://www.cve.org/CVERecord?id=CVE-2024-37371"},{"name":"CVE-2023-38545","url":"https://www.cve.org/CVERecord?id=CVE-2023-38545"}],"links":[],"reference":"CERTFR-2025-AVI-0492","revisions":[{"description":"Version initiale","revision_date":"2025-06-11T00:00:00.000000"}],"risks":[{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"\u00c9l\u00e9vation de privil\u00e8ges"},{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"},{"description":"Atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es"},{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Non sp\u00e9cifi\u00e9 par l'\u00e9diteur"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Siemens. Certaines d'entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens","vendor_advisories":[{"published_at":"2025-06-10","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-082556","url":"https://cert-portal.siemens.com/productcert/html/ssa-082556.html"},{"published_at":"2025-06-10","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-633269","url":"https://cert-portal.siemens.com/productcert/html/ssa-633269.html"},{"published_at":"2025-06-10","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-693776","url":"https://cert-portal.siemens.com/productcert/html/ssa-693776.html"}]}